Quantité minimale : 1
Quantité :
Product ID | P11189 |
Accessories (in scope of delivery) | 2 x gasket G1/2 AFM 34 |
Maximum values | Ui = 13.65 V / li = 200 mA / Pi = 0.69 W / Ci = 0.45 nF / Li = 1.80 µH |
Protection [EN 60529] | IP 67 |
Material housing | stainless steel AISI 316 Ti, brass |
Compressive strength | 60 bar |
Sensor length L | 110 mm |
ATEX marking gas | Ex II 1 G Ex ia IIC T6…T3 Ga |
Electrical connection | 2 m PUR-cable, 4x0.25 mm² |
Material sensor touched by medium | stainless steel AISI 316 Ti |
Reaction time typ. | 2 s (1 ... 13 s) |
Temperature range dust-Ex | -20 ... 85 °C |
Detection range Oil | 3 ... 200 cm/s |
Process connection | G1/2 |
Output | output with separate Amplifier |
Marking gas Ex for partition wall mounting | Ex II 1/2 G Ex ia IIC T6…T3 Ga/Gb |
TYPE | STS 110 K-L110 |
Associated amplifiers | SZAb 400 EX-GR, SZAb 400 EX-WR115, SZAb 400 EX-WR230, SZAb 400 EX-GA |
Temperature range in T4 | -20 ... 85 °C |
Temperature range in T5 | -20 ... 55 °C |
ATEX Certificate | TÜV 98 ATEX 1298 X |
Temperature range in T6 | -20 ... 40 °C |
Ex area uf use | installation in partition wall Zone 0/1, Zone 0, Zone 20 |
Temperature range in T3 | -20 ... 85 °C |
Detection range water | 1 ... 100 cm/s |
ATEX Marking dust | Ex II 1 D Ex ia IIIC T125°C Da |
Medium | Water, oil |
Start-up time typ. | 8 s (2 ... 18 s) |
Note | probe with longer cable available on request |